Dunlop Reports It requires two wires (normally a black one and a white one) to create a circuit. With modern wiring, these two wires (along with a ground wire) are bundled together in a single plastic sheathing. Older knob and tube wiring was installed so that the black wire and the white wire ran separately. It was installed in houses up until about 1950. Modern wiring runs directly through holes in the structural components (such as floor joists). Knob and tube wiring used protective ceramic tubes placed in the holes to prevent the wire from chafing against the woodwork. Modern wiring uses staples to hold the wiring against structural members. Knob and tube wiring used more elaborate ceramic knobs to clamp the wire
to the structural member. Connections between modern wires are completed
within enclosed junction boxes. Knob and tube wiring had visible connections.
The wires were spliced and soldered together and then wrapped with electrical
tape. Ceramic knobs were used to secure the wires so that anyone inadvertently
tugging on the wire would not be tugging on the electrical connection. Modern
wiring is typically #14 gauge copper wire and capable of handling 15 amps.
Knob and tube wiring is often #12 gauge copper wire and can handle 20 amps.
Note: Even though some knob and tube wiring is capable of handling 20 amps,
we suggest that it be protected by 15 amp fuses because, in all likelihood,
some modern #14 gauge wire may be connected to the older #12 gauge wiring. A ground conductor is necessary if you are plugging in appliances that have a 3-prong plug. If however, the knob and tube wiring is restricted to bedrooms, living room, dining room, et cetera, this creates no special hazard. Plugging a two prong lamp, TV, or clock into an old two prong outlet is just as safe as plugging them into a grounded outlet. We feel that the insurance companies’ rejection of knob and tube wiring is a knee jerk reaction reminiscent of the immediate reactions to UFFI and aluminum wiring. We are hoping that the insurance industry will realize that this is not a black and white issue (no pun intended) and that the mere presence of knob and tube wiring does not, in itself, create a hazard. We feel the same way about 60 amp services, but that’s another story. <<Back to Report Library |
|||
|
|||