The Standards of
Practice are a set of guidelines for home inspectors to follow in the
performance of their home inspections.We follow the Standards
of Practice of both OAHI and ASHI. They are the most widely accepted
home inspection guidelines in use,
and
include
all of
the home's
major
systems and components. The Standards of Practice and Code of Ethics
in this booklet are recognized by many government, professional,
and
legal authorities as the definitive standard for professional performance.
Glossary
Note: Italicized words are defined in the Glossary.
1. INTRODUCTION
1.1 The American
Society of Home Inspectors (ASHI) is a not-for-profit professional
society established in 1976. Membership in ASHI is voluntary
and its members include private, fee-paid home inspectors. ASHI's
objectives include promotion of excellence within the profession
and continual improvement of its members' inspection services
to the public.
2. PURPOSE AND SCOPE
2.1 The purpose
of these Standards of Practice is to establish a minimum and
uniform standard for private, fee-paid home inspectors who are
members of the American Society of Home Inspectors. Home Inspections
performed to these Standards of Practice are intended to provide
the client with information regarding the condition of the systems
and components of the home as inspected at the time of the Home
Inspection.
- provide the client
with a better understanding of the property conditions, as observed at the time of the inspection.
- readily accessible systems and components of homes listed
in these Standards of Practice.
- installed systems and components of homes listed in these
Standards of Practice.
B.
report:
- on those systems and components inspected which, in the professional
opinion of the inspector, are significantly deficient or are
near the end of their service lives.
- a reason why, if not self-evident, the system or component
is significantly deficient or near the end of its service life.
- the
inspector's recommendations to correct or monitor the reported
deficiency.
- on any systems and components designated for inspection in
these Standards of Practice which were present at the time
of the Home Inspection but were not inspected and a reason
they were not inspected.
2.3 These Standards
are not intended to limit inspectors from:
A. including
other inspection services, systems or components in addition
to those required by these Standards of Practice.
B. specifying repairs, provided the inspector is appropriately
qualified and willing to do so.
C. excluding systems and components from the inspection
if requested by the client.
3. STRUCTURAL COMPONENTS
3.1 The inspector
shall:
A. inspect:
- the structural components including foundation and framing.
- by probing a representative number of structural components
where deterioration is suspected or where clear indications of
possible deterioration exist. Probing is NOT required when probing
would damage any finished surface or where no deterioration is
visible.
B: describe:
- the foundation and report the methods used to inspect the under-floor
crawl space
- the floor
structure.
- the wall
structure.
- the ceiling
structure.
- the roof
structure and report the methods used to inspect
the attic.
3.2 The inspector
is NOT required to:
A. provide any engineering service
or architectural service.
B. offer an opinion as to the adequacy of any structural
system or component.
4.
EXTERIOR
4.1 The
inspector shall:
A. inspect:
- the exterior
wall covering, flashing and trim.
- all exterior
doors.
- attached
decks, balconies, stoops, steps, porches, and their associated
railings.
- the eaves,
soffits, and fascias where accessible from the ground level.
- the vegetation,
grading, surface drainage, and retaining walls on the property
when any of these are likely to adversely affect the building.
- walkways, patios, and driveways leading to dwelling entrances.
- describe
the exterior wall covering.
4.2 The
inspector is NOT required to:
A. inspect:
- screening,
shutters, awnings, and similar seasonal accessories.
- fences.
- Geological,
geotechnical, or hydrological conditions.
- recreational
facilities.
- outbuildings.
- seawalls,
break-walls, and docks.
- erosion control
and earth stabilization measures.
5.
ROOF SYSTEM
5.1 The
inspector shall:
A. inspect:
- the roof
covering.
- the roof
drainage systems.
- the flashings.
- the skylights,
chimneys, and roof penetrations.
- describe
the roof covering and report the methods used to inspect
the roof.
5.2 The inspector
is NOT required to:
A. inspect:
- antennae.
- interiors
of flues or chimneys which are not readily
accessible.
- other installed
accessories.
6.
PLUMBING SYSTEM
6.1 The
inspector shall:
A. inspect:
- the
interior water supply and distribution systems including
all fixtures
and faucets.
- the drain,
waste and vent systems including all fixtures.
- the water heating equipment.
- the vent systems , flues, and chimneys.
- the fuel
storage and fuel distribution systems.
- the drainage
sumps, sump pumps, and related piping.
B.
describe:
- the water
supply, drain, waste, and vent piping materials.
- the water
heating equipment including the energy source.
- the location
of main water and main fuel shut-off valves.
6.2 The
inspector is NOT required to:
A. inspect:
- the clothes
washing machine connections.
- the interiors
of flues or chimneys which are not readily
accessible.
- wells, well
pumps, or water storage related equipment.
- water conditioning
systems.
- solar water
heating systems.
- fire and
lawn sprinkler systems.
- private waste
disposal systems.
B. determine:
- whether
water supply and waste disposal systems are public or private.
- the quantity
or quality of the water supply.
- operate safety
valves or shut off valves.
7.
ELECTRICAL SYSTEM
7.1 The inspector
shall:
A. inspect:
- the service
drop.
- the service
entrance conductors, cables, and raceways.
- the service
equipment and main disconnects.
- the service grounding.
- the interior components of service panels and sub panels.
- the conductors.
- the overcurrent
protection devices.
- a representative
number of installed lighting
fixtures, switches, and receptacles.
- the ground
fault circuit interrupters.
B. describe:
- the amperage
and voltage rating of the service
- the location
of main disconnect(s) and sub panels
- the wiring
methods
C. report:
- on the presence
of solid conductor aluminum branch circuit wiring
- on the absence
of smoke detectors
7.2 The inspector
is NOT required to:
A. inspect:
- the remote
control devices unless the device is the only control device.
- the alarm
systems and components.
- the low
voltage wiring, systems and components.
- the ancillary
wiring, systems and components not a part of the primary
electrical power distribution system.
- measure amperage,
voltage, or impedance.
8.
HEATING SYSTEM
8.1 The inspector
shall:
A. inspect:
- the installed
heating equipment.
- the vent
systems, flues, and chimneys.
B. describe:
- the energy
source.
- the heating
method by its distinguishing characteristics.
8.2 The inspector
is NOT required to:
A. inspect:
- the interiors
of flues or chimneys which are not readily
accessible.
- the heat
exchanger.
- the humidifier
or dehumidifier.
- the electronic
air filter.
- the solar
space heating system.
- determine
heat supply adequacy or distribution balance.
9.
AIR CONDITIONING SYSTEMS
9.1 The inspector
shall:
A. inspect the installed
central and through-wall cooling equipment.
B. describe:
- the energy
source.
- the cooling
method by its distinguishing characteristics.
9.2 The inspector
is NOT required to:
A. inspect electronic air filters.
B. determine cooling supply adequacy or distribution balance.
10.
INTERIOR
10.1 The
inspector shall:
A. inspect:
- the walls,
ceilings, and floors.
- the steps,
stairways, and railings.
- the countertops
and a representative number of
installed cabinets.
- a representative
number of doors and windows.
- garage doors
and garage door operators.
10.2 The inspector is NOT required to:
A. inspect:
- the paint,
wallpaper, and other finish treatments.
- the carpeting.
- the window
treatments.
- the central
vacuum systems.
- the household
appliances.
- recreational
facilities.
11.
INSULATION & VENTILATION
11.1 The
inspector shall:
A. inspect:
- the insulation
and vapor retarders in unfinished spaces.
- the ventilation
of attics and foundation areas.
- the mechanical
ventilation systems.
describe:
- the insulation
and vapor retarders in unfinished spaces.
- the absence
of insulation in unfinished spaces at conditioned surfaces.
11.2 The
inspector is NOT required to:
A. disturb insulation or vapor retarders.
B. determine indoor air quality.
12.
FIREPLACES AND SOLID FUEL BURNING APPLIANCES
12.1 The
inspector shall:
A. inspect :
- the system
components.
- the vent
systems, flues, and chimneys.
B. describe:
- the fireplaces
and solid fuel burning appliances.
- the chimneys.
12.2 The
inspector is NOT required to:
A. inspect:
- the interiors
of flues or chimneys.
- the firescreens
and doors.
- the seals
and gaskets.
- the automatic
fuel feed devices.
- the mantles
and fireplace surrounds.
- the combustion
make-up air devices.
- the heat
distribution assists whether gravity controlled or fan assisted.
- ignite
or extinguish fires.
- determine
draft characteristics.
- move fireplace
inserts or stoves or firebox contents.
13. GENERAL LIMITATIONS AND EXCLUSIONS
13.1 General limitations:
A.
Inspections performed in accordance with these Standards of Practice
- are not technically
exhaustive.
- will not identify
concealed conditions or latent defects
These
Standards are applicable to buildings with four or less dwelling
units and their garages or carports.
13.2 General exclusions:
A. The
inspector is not required to perform any action or make any determination
unless specifically stated in these Standards of Practice, except
as may be required by lawful authority.
B. Inspectors
are NOT required to determine:
- the condition
of systems or components
which are not readily accessible.
- the remaining
life of any system or component.
- the strength,
adequacy, effectiveness, or efficiency of any system or component.
- the causes
of any condition or deficiency.
- the methods,
materials, or costs of corrections.
- future conditions
including, but not limited to, failure of systems and components.
- the suitability
of the property for any specialized use.
- compliance
with regulatory requirements (codes, regulations, laws, ordinances,
etc.).
- the market
value of the property or its marketability.
- the advisability
of the purchase of the property.
- the presence
of potentially hazardous plants or animals including, but not
limited to wood destroying organisms or diseases harmful to humans.
- the presence
of any environmental hazards including, but not limited to toxins,
carcinogens, noise, and contaminants in soil, water, and air.
- the effectiveness
of any system installed or methods utilized to control
or remove suspected hazardous substances.
- the operating
costs of systems or components.
- the acoustical
properties of any system or component.
Inspectors
are NOT required to offer:
- or perform
any act or service contrary to law.
- or perform
engineering services. or perform
work in any trade
- or any professional
service other than home inspection.
- warranties
or guarantees of any kind.
Inspectors
are NOT required to operate:
- any system
or component which is shut down
or otherwise inoperable.
- any system
or component which does not respond to normal
operating controls.
- shut-off
valves.
Inspectors
are NOT required to enter:
- any area
which will, in the opinion of the inspector, likely be
dangerous to the inspector or other persons or damage the property
or its systems or components.
- the under-floor crawl spaces or attics which are not readily
accessible.
Inspectors
are NOT required to inspect:
- underground items including, but not limited to underground
storage tanks or other underground indications of their presence,
whether abandoned or active.
- systems or
components which are not installed.
- decorative
items.
- systems
or components located in areas which are not entered in accordance
with these Standards of Practice.
- detached
structures other than garages and carports.
- common elements
or common areas in multi-unit housing, such as condominium properties
or cooperative housing.
Inspectors
are NOT required to:
- perform any procedure or operation which will, in the opinion
of the inspector, likely be dangerous to the inspector or other
persons or damage the property or it's systems or components.
- move suspended ceiling tiles, personal property, furniture,
equipment, plants, soil, snow, ice, or debris.
- dismantle
any system or component, except as explicitly required by these
Standards of Practice.
GLOSSARY
GLOSSARY of
ITALICIZED WORDS*
Alarm
Systems
Warning devices, installed or free-standing, including but not limited
to; carbon monoxide detectors, flue gas and other spillage detectors,
security equipment, ejector pumps and smoke alarms
Architectural
Service
Any practice involving the art and science of building design for construction
of any structure or grouping of structures and the use of space within
and surrounding the structures or the design for construction, including
but not specifically limited to, schematic design, design development,
preparation of construction contract documents, and administration of
the construction contract
Automatic
Safety Controls
Devices designed and installed to protect systems and components from
unsafe conditions
Component
A part of a system
Decorative
Ornamental; not required for the proper operation of the essential systems
and components of a home
Describe
To report a system or component by its type or other observed, significant
characteristics to distinguish it from other systems or components
Dismantle
To take apart or remove any component, device or piece of equipment
that would not be taken apart or removed by a homeowner in the course
of normal and routine home owner maintenance
Engineering
Service
Any professional service or creative work requiring engineering education,
training, and experience and the application of special knowledge of
the mathematical, physical and engineering sciences to such professional
service or creative work as consultation, investigation, evaluation,
planning, design and supervision of construction for the purpose of
assuring compliance with the specifications and design, in conjunction
with structures, buildings, machines, equipment, works or processes
Further
Evaluation
Examination and analysis by a qualified professional, tradesman or service
technician beyond that provided by the home inspection
Home
Inspection
The process by which an inspector visually examines the readily accessible
systems and components of a home and which describes those systems and
components in accordance with these Standards of Practice
Household
Appliances
Kitchen, laundry, and similar appliances, whether installed or free-standing
Inspect
To examine readily accessible systems and components of a building in
accordance with these Standards of Practice, using normal operating
controls and opening readily openable access panels
Inspector
A person hired to examine any system or component of a building in accordance
with these Standards of Practice
Installed
Attached such that removal requires tools
Normal
Operating Controls
Devices such as thermostats, switches or valves intended to be operated
by the homeowner
Readily
Accessible
Available for visual inspection without requiring moving of personal
property, dismantling, destructive measures, or any action which will
likely involve risk to persons or property
Readily
Openable Access Panel
A panel provided for homeowner inspection and maintenance that is within
normal reach, can be removed by one person, and is not sealed in place
Recreational
Facilities
Spas, saunas, steam baths, swimming pools, exercise, entertainment,
athletic, playground or other similar equipment and associated accessories
Report
To communicate in writing
Representative
Number
One component per room for multiple similar interior components such
as windows and electric outlets; one component on each side of the building
for multiple similar exterior components
Roof
Drainage Systems
Components used to carry water off a roof and away from a building
Significantly
deficient
unsafe or not functioning
Shut
Down
A state in which a system or component cannot be operated by normal
operating controls
Solid
Fuel Burning Appliances
A hearth and fire chamber or similar prepared place in which a fire
may be built and which is built in conjunction with a chimney; or a
listed assembly of a fire chamber, its chimney and related factory-made
parts designed for unit assembly without requiring field construction
Structural
Component
A component which supports non-variable forces or weights (dead loads)
and variable forces or weights (live loads)
System
A combination of interacting or interdependent components, assembled
to carry out one or more functions
Technically
Exhaustive
An investigation that involves dismantling, the extensive use of advanced
techniques, measurements, instruments, testing, calculations, or other
means
Under-floor
Crawl Space
The area within the confines of the foundation and between the ground
and the underside of the floor
Unsafe
A condition in a readily accessible, installed component or system which
is judged to be a significant risk of personal injury during normal,
day-to-day use. The risk may be due to damage, deterioration, improper
installation or a change in accepted residential construction standards.
Wiring
Methods
Identification of electrical conductors or wires by their general type,
such as "non-metallic sheathed cable" ("Romex"), "armored cable" ("bx")
or "knob and tube," etc.
*Note: In these Standards of Practice, redundancy in
the description of the requirements, limitations and exclusions regarding
the scope of the Home Inspection is provided for clarity.
Copyright 2000 American Society of Home